Hospital endoscopic cleaning sterile RO pure water treatment system is a very important equipment in the medical field, used to provide high purity, sterile water to ensure the cleaning and disinfection of medical equipment and instruments. Here is some expertise on cleaning sterile pure water treatment systems in hospitals:

1. Composition of the processing system:
- Pretreatment unit: including sand filter, carbon filter, softening, etc., used to remove impurities, organic matter and hardness from water.

Reverse osmosis (RO) unit: removal of ions, microorganisms and macromolecules from water through a semi-permeable membrane.

- Ultraviolet (UV) disinfection unit: ultraviolet light is used to kill bacteria and viruses in water.

- Storage and distribution system: used to store sterile pure water after treatment and distribute it to various points of use.

2. Processing process:
- Raw water enters the pretreatment unit, and after treatment such as filtration and softening, enters the reverse osmosis unit.

- The reverse osmosis unit removes most of the ions, microorganisms and macromolecules, the resulting concentrated water is discharged, and the produced water enters the ultraviolet disinfection unit.

- The UV disinfection unit sterilizes the produced water to kill bacteria and viruses.

- The water produced after disinfection enters the ultrafiltration unit to further remove microorganisms and macromolecular organic matter.

- Enter the storage and distribution system and pipe it to various points of use.

3. Sterility guarantee:

- Multistage filtration and disinfection measures are used to ensure that the treated water meets the requirements of sterility.

- Disinfect and maintain the system regularly to prevent the growth of bacteria and viruses.

- Disinfect and maintain the system regularly to prevent the growth of bacteria and viruses.

4. Water quality index:

- Conductivity: An indicator of the content of ions in water, the lower the water is, the purer the water is.

- Microbial content: including the total number of bacteria, coliform, etc., should meet the requirements of sterility.

- Organic content: such as total organic carbon (TOC), the lower the water quality is better.

- Particle content: The relevant standards should be met to ensure the cleanliness of the water.

5. System maintenance:

- Replace the filter element and reverse osmosis membrane of the pretreatment unit regularly to ensure the normal operation of the system.

- Regularly clean the UV disinfection unit to prevent dirt accumulation affecting the disinfection effect.

- Regular testing and maintenance of the system to ensure stable water quality.

6. Precautions:

- Operators should be professionally trained to understand system operation and maintenance methods.

- The system should be installed in a well-ventilated, dry environment, away from direct sunlight.

- Disinfect and maintain the system regularly to ensure safe water quality.

- When the system fails, it should be shut down and repaired in time to avoid affecting the normal use.

CSSY Hospital Endoscopic Cleaning Department Pure Water Machine Instrument Installation Case:

Endoscopic cleaning pure water system7et Endoscopic cleaning pure waterdob Endoscopic cleaning water instrumentvx8 Endoscopic cleaning wateryru

Hospital Clinical Laboratory Ultrapure Reverse Osmosis Water Treatment Systems Supplier

Contact Ways,Distributors are Welcome to Contact Us.

aliceguo@ssywater.com

0086 186 2808 9205

aliceguo@ssywatercsf aliceguo@ssywatero72